摘要:
虽然传统全膝关节置换术(TKA)是目前治疗终末期膝骨关节炎的首选方法,但大量研究发现术后仍存在 疼痛、关节不稳定、翻修率高等问题,其中软组织失衡是导致这些问题的关键因素之一。近些年,压力传感器系统被 引入以解决上述问题,但其临床疗效尚存争议。该文就压力传感器辅助TKA 的优势及局限性,以及与机器人系统联 合应用进行综述。
Abstract:
-

参考文献/References

[1] Canovas F, Dagneaux L. Quality of life after total knee arthroplasty[J]. Orthop Traumatol Surg Res, 2018, 104(1S): S41-S46.
[2] Alcelik IA, Blomfield MI, Diana G, et al. A comparison of shortterm outcomes of minimally invasive computer-assisted vs minimally invasive conventional instrumentation for primary total knee arthroplasty: a systematic review and meta-analysis[J]. J Arthroplasty, 2016, 31(2): 410-418.
[3] Allom RJ, Wood JA, Chen DB, et al. Tibiofemoral dynamic stressed gap laxities correlate with compartment load measurements in robotic arm-assisted total knee arthroplasty[J]. Bone Jt Open, 2021, 2(11):974-980.
[4] Lewis PL, Robertsson O, Graves SE, et al. Variation and trends in reasons for knee replacement revision: a multi-registry study of revision burden[J]. Acta Orthop. 2021, 92(2): 182-188.
[5] Harris ML, Morberg P, Bruce WJM, et al. An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film[J]. J Biomech, 1999, 32(9): 951-958.
[6] Park CH, Song SJ. Sensor-assisted total knee arthroplasty: a narrative review[J]. Clin Orthop Surg, 2021, 13(1): 1-9.
[7] Giuntoli M, Scaglione M, Bonicoli E, et al. Intraoperative load sensing in total knee arthroplasty leads to a functional but not clinical difference: a comparative, gait analysis evaluation[J]. J Funct Morphol Kinesiol, 2022, 7(1): 23.
[8] Wood TJ, Winemaker MJ, Williams DS, et al. Randomized controlled trial of sensor-guided knee balancing compared to standard balancing technique in total knee arthroplasty[J]. J Arthroplasty, 2021, 36(3): 953-957.
[9] Cidambi KR, Robertson N, Borges C, et al. Intraoperative comparison of measured resection and gap balancing using a force sensor: a prospective, randomized controlled trial[J]. J Arthroplasty, 2018, 33(7): S126-S130.
[10] Chow JC, Breslauer L. The use of intraoperative sensors significantly increases the patient-reported rate of improvement in primary total knee arthroplasty[J]. Orthopedics, 2017, 40(4): e648-e651.
[11] Gustke KA, Golladay GJ, Roche MW, et al. Primary TKA patients with quantifiably balanced soft-tissue achieve significant clinical gains sooner than unbalanced patients[J]. Adv Orthop, 2014, 2014: 628695.
[12] Manning WA, Blain A, Longstaff L, et al. A load-measuring device can achieve fine-tuning of mediolateral load at knee arthroplasty but may lead to a more lax knee state[J]. Knee Surg Sports Traumatol Arthrosc, 2019, 27(7): 2238-2250.
[13] MacDessi SJ, Gharaibeh MA, Harris IA. How accurately can soft tissue balance be determined in total knee arthroplasty?[J]. J Arthroplasty, 2019, 34(2): 290-294. e1.
[14] Yapp LZ, Robinson PG, Clement ND, et al. Total knee arthroplasty and intra-articular pressure sensors: can they assist surgeons with intra-operative decisions?[J]. Curr Rev Musculoskelet Med, 2021, 14(6): 361-368.
[15] Begum FA, Kayani B, Magan AA, et al. Current concepts in total knee arthroplasty: mechanical, kinematic, anatomical, and functional alignment[J]. Bone Jt Open, 2021, 2(6): 397-404.
[16] Deckard ER, Ziemba-Davis M, Meneghini RM. Tibiofemoral contact forces influence intraoperative kinematic pivot pattern dependent on posterior cruciate ligament resection in primary total knee arthroplasty[J]. J Am Acad Orthop Surg Glob Res Rev, 2022, 6(4): e22.00033.
[17] Cochetti A, Ghirardelli S, Iannotti F, et al. Sensor-guided technology helps to reproduce medial pivot kinematics in total knee arthroplasty[J]. J Orthop Surg (Hong Kong), 2020, 28(3): 2309499020966133.
[18] Meere PA, LaMont JG, Baez J, et al. Surgeon assessment of gapping versus kinetic loading using intraoperative sensors during TKA[J]. Reconstr Rev, 2015, 5(3): 29-34.
[19] Walker LC, Clement ND, Ghosh KM, et al. What is a balanced knee replacement?[J]. EFORT Open Rev, 2018, 3(12): 614-619.
[20] Gustke KA, Golladay GJ, Roche MW, et al. A new method for defining balance: promising short-term clinical outcomes of sensorguided TKA[J]. J Arthroplasty, 2014, 29(5): 955-960.
[21] Meneghini RM, Ziemba-Davis MM, Lovro LR, et al. Can intraoperative sensors determine the“ target” ligament balance? Early outcomes in total knee arthroplasty[J]. J Arthroplasty, 2016, 31(10): 2181-2187.
[22] Risitano S, Karamian B, Indelli PF. Intraoperative load-sensing drives the level of constraint in primary total knee arthroplasty: surgical technique and review of the literature[J]. J Clin Orthop Trauma, 2017, 8(3): 265-269.
[23] Zhao R, Liu Y, Tian H. Accuracy of soft tissue balancing in total knee arthroplasty using surgeon-defined assessment versus a gap-balancer or electronic sensor[J]. J Orthop Surg Res, 2021, 16(1): 305.
[24] Nicolet-Petersen SJ, Howell SM, Hull ML. Tibial contact force and contact location errors of the VERASENSE[J]. J Biomech Eng, 2018, 140(12): 124502.
[25] Elmallah RK, Mistry JB, Cherian JJ, et al. Can we really “feel” a balanced total knee arthroplasty?[J]. J Arthroplasty, 2016, 31(9 suppl): 102-105.
[26] Song SJ, Lee HW, Kim KI, et al. Load imbalances existed as determined by a sensor after conventional gap balanc-ing with a tensiometer in total knee arthroplasty[J]. Knee Surg Sports Traumatol Arthrosc, 2020, 28(9): 2953-2961.
[27] Bellemans, J, D’Hooghe P, Vandenneucker H, et al. Soft tissue balance in total knee arthroplasty: does stress relaxation occur perioperatively?[J]. Clin Orthop Relat Res, 2006, 452: 49-52.
[28] 孙茂淋, 杨柳, 何锐. 手术机器人在人工全膝关节置换术中的应 用及研究进展[J]. 中国修复重建外科杂志, 2021, 35(7): 913-917.
[29] 王俏杰, 张先龙. 机器人辅助人工全膝关节置换术中下肢对线选 择与软组织平衡策略[J]. 中国修复重建外科杂志, 2021, 35(10): 1221-1226.
[30] Chow J, Law TY, Roche M. Sensor-based soft tissue balancing in total knee arthroplasty[J]. Adv Exp Med Biol, 2018, 1093: 327-334.
[31] Gordon AC, Conditt MA, Verstraete MA. Achieving a balanced knee in robotic TKA[J]. Sensors (Basel), 2021, 21(2): 535.
[32] Bardou-Jacquet J, Murgier J, Laudet F, et al. Combining load sensor and robotic technologies for ligament balance in total knee arthroplasty[J]. Orthop Traumatol Surg Res, 2022,108(5): 102889.
[33] Song SJ, Kang SG, Lee YJ, et al. An intraoperative load sensor did not improve the early postoperative results of posterior-stabilized TKA for osteoarthritis with varus deformities[J]. Knee Surg Sports Traumatol Arthrosc, 2019, 27(5): 1671-1679.

备注/Memo

备注/Memo:
通信作者:王晋东 E-mai: gkbswjd@126.com
更新日期/Last Update: 2022-12-01