索引超出了数组界限。 文章摘要
|本期目录/Table of Contents|

[1]田宇辰,张伟.空心螺钉治疗青壮年垂直型股骨颈骨折[J].国际骨科学杂志,2021,05:280-284.
点击复制

空心螺钉治疗青壮年垂直型股骨颈骨折(PDF)

《国际骨科学杂志》[ISSN:1673-7083/CN:31-1952/R]

期数:
2021年05期
页码:
280-284
栏目:
综述
出版日期:
2021-10-01

文章信息/Info

Title:
-
作者:
田宇辰张伟
200233, 上海交通大学附属第六人民医院骨科
Author(s):
-
关键词:
垂直型股骨颈骨折 内固定 空心螺钉
Keywords:
-
分类号:
-
DOI:
10.3969/j.issn.1673-7083.2021.05.005
文献标识码:
-
摘要:
青壮年股骨颈骨折常因高能量损伤机制引起,多为垂直型骨折。对于此类骨折临床上建议行内固定治疗,但对内固定方式的选择目前存在争议。空心螺钉是常见的内固定方式,其创伤小、易操作,但生物力学性能较弱,易导致骨不连、骨坏死、畸形愈合等并发症发生,为此很多学者对其进行了改良。该文对空心螺钉治疗青壮年垂直型股骨颈骨折的研究进展作一综述。
Abstract:
-

参考文献/References

[1] Gillespie WJ. Extracts from "clinical evidence": hip fracture[J]. BMJ, 2001, 322(7292): 968-975.
[2] Ye Y, Hao J, Mauffrey C, et al. Optimizing stability in femoral neck fracture fixation[J]. Orthopedics, 2015, 38(10): 625-630.
[3] Xu JL, Liang ZR, Xiong BL, et al. Risk factors associated with osteonecrosis of femoral head after internal fixation of femoral neck fracture:a systematic review and meta-analysis[J]. BMC Musculoskelet Disord, 2019, 20(1): 632.
[4] Bartonícek J. Pauwels' classification of femoral neck fractures: correct interpretation of the original[J]. J Orthop Trauma, 2001, 15(5): 358-360.
[5] Zhang YL, Zhang W, Zhang CQ. A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws[J]. Orthop Traumatol Surg Res, 2017, 103(2): 229-234.
[6] Slobogean GP, Sprague SA, Scott T, et al. Complications following young femoral neck fractures[J]. Injury, 2015, 46(3): 484-491.
[7] Wang SH, Yang JJ, Shen HC, et al. Using a modified Pauwels method to predict the outcome of femoral neck fracture in relatively young patients[J]. Injury, 2015, 46(10): 1969-1974.
[8] Ye Y, Chen K, Tian K, et al. Medial buttress plate augmentation of cannulated screw fixation in vertically unstable femoral neck fractures: surgical technique and preliminary results[J]. Injury, 2017, 48(10): 2189-2193.
[9] Cha YH, Ji YO, Hwang SY, et al. Biomechanical evaluation of internal fixation of pauwels type Ⅲ femoral neck fractures: a systematic review of various fixation methods[J]. Clin Orthop Surg, 2019, 11(1): 1-14.
[10] Sciacca S, Lidder SS, Grechenig C, et al. Variations of treatment in selected proximal femur fractures among surgeons with different surgical experience:a survey at an international AO course[J]. Injury, 2015, 46(Suppl 6): S57-S60.
[11] Augat P, Bliven E, Hackl S. Biomechanics of femoral neck fractures and implications for fixation[J]. J Orthop Trauma, 2019, 33(Suppl 1): S27-S32.
[12] Luttrell K, Beltran M, Collinge CA. Preoperative decision making in the treatment of high-angle "vertical" femoral neck fractures in young adult patients. An expert opinion survey of the Orthopaedic Trauma Association's(OTA)membership[J]. J Orthop Trauma, 2014, 28(9): e221-e225.
[13] Samsami S, Augat P, Rouhi G. Stability of femoral neck fracture fixation: a finite element analysis[J]. Proc Inst Mech Eng H, 2019, 233(9): 892-900.
[14] Samsami S, Saberi S, Bagheri N, et al. Interfragmentary motion assessment for three different fixation techniques of femoral neck fractures in young adults[J]. Biomed Mater Eng, 2016, 27(4): 389-404.
[15] Samsami S, Saberi S, Sadighi S, et al. Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerical investigations[J]. J Med Biol Eng, 2015, 35(5): 566-579.
[16] Panteli M, Rodham P, Giannoudis PV. Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly[J]. Injury, 2015, 46(3): 445-452.
[17] Zdero R, Keast-Butler O, Schemitsch EH. A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model[J]. J Trauma, 2010, 69(6): 1537-1544.
[18] Trikha V, Kumar A, Mittal S, et al. Risk of bony violation with standard triple screw configurations for fixation of femoral neck fractures: a preliminary computed tomography based analysis[J]. J Clin Orthop Trauma, 2020, 11(Suppl 4): S546-S552.
[19] Wright DJ, Bui CN, Ihn H, et al. Posterior inferior comminution significantly influences torque to failure in vertically oriented femoral neck fractures: a biomechanical study[J]. J Orthop Trauma, 2020, 34(12): 644-649.
[20] Li J, Wang M, Zhou J, et al. Optimum configuration of cannulated compression screws for the fixation of unstable femoral neck fractures: finite element analysis evaluation[J]. Biomed Res Int, 2018, 2018: 1271762.
[21] Jiang D, Zhan S, Wang L, et al. Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures[J]. J Orthop Res, 2021, 39(8): 1669-1680.
[22] Zhao G, Liu C, Chen K, et al. Nonanatomical reduction of femoral neck fractures in young patients(≤65 years old)with internal fixation using three parallel cannulated screws[J]. Biomed Res Int, 2021, 2021: 3069129.
[23] Slobogean GP, Stockton DJ, Zeng BF, et al. Femoral neck shortening in adult patients under the age of 55 years is associated with worse functional outcomes: analysis of the prospective multi-center study of hip fracture outcomes in China(SHOC)[J]. Injury, 2017, 48(8): 1837-1842.
[24] Liu Y, Ai ZS, Shao J, et al. Femoral neck shortening after internal fixation[J]. Acta Orthop Traumatol Turc, 2013, 47(6): 400-404.
[25] Weil YA, Khoury A, Zuaiter I, et al. Femoral neck shortening and varus collapse after navigated fixation of intracapsular femoral neck fractures[J]. J Orthop Trauma, 2012, 26(1): 19-23.
[26] Hawks MA, Kim H, Strauss JE, et al. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone[J]. Clin Biomech(Bristol, Avon), 2013, 28(8): 886-891.
[27] Guimarães JAM, Rocha LR, Noronha Rocha TH, et al. Vertical femoral neck fractures in young adults: a closed fixation strategy using a transverse cancellous lag screw[J]. Injury, 2017, 48(Suppl 4): S10-S16.
[28] Kuan FC, Hsu KL, Lin CL, et al. Biomechanical properties of off-axis screw in Pauwels Ⅲ femoral neck fracture fixation: bicortical screw construct is superior to unicortical screw construct[J]. Injury, 2019, 50(11): 1889-1894.
[29] Dong Q, Han Z, Zhang YG, et al. Comparison of transverse cancellous lag screw and ordinary cannulated screw fixations in treatment of vertical femoral neck fractures[J]. Orthop Surg, 2019, 11(4): 595-603.
[30] Zhou L, Lin J, Huang A, et al. Modified cannulated screw fixation in the treatment of Pauwels type Ⅲ femoral neck fractures: a biomechanical study[J]. Clin Biomech(Bristol, Avon), 2020, 74: 103-110.
[31] Johnson JP, Borenstein TR, Waryasz GR, et al. Vertically oriented femoral neck fractures: a biomechanical comparison of 3 fixation constructs[J]. J Orthop Trauma, 2017, 31(7): 363-368.
[32] Filipov O. Biplane double-supported screw fixation(F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck[J]. Eur J Orthop Surg Traumatol, 2011, 21(7): 539-543.
[33] Tianye L, Peng Y, Jingli X, et al. Finite element analysis of different internal fixation methods for the treatment of Pauwels type Ⅲ femoral neck fracture[J]. Biomed Pharmacother, 2019, 112: 108658.
[34] Boraiah S, Paul O, Hammoud S, et al. Predictable healing of femoral neck fractures treated with intraoperative compression and length-stable implants[J]. J Trauma, 2010, 69(1): 142-147.
[35] Zhang B, Liu J, Zhang W. Ordinary cannulated compression screws or headless cannulated compression screws? A synthetic bone biomechanical research in the internal fixation of vertical femoral neck fracture[J]. Biomed Res Int, 2018,2018: 4898301.
[36] Weil YA, Qawasmi F, Liebergall M, et al. Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures[J]. Arch Orthop Trauma Surg, 2018, 138(5): 661-667.
[37] Zhang B, Liu J, Zhu Y, et al. A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures[J]. Int Orthop, 2018, 42(8): 1949-1955.
[38] Li J, Wang M, Zhou J, et al. Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures[J]. Injury, 2020, 51(4): 995-1003.
[39] Lu H, Shen H, Zhou S, et al. Biomechanical analysis of the computer-assisted internal fixation of a femoral neck fracture[J]. Genes Dis, 2020, 7(3): 448-455.
[40] Zhang Y, Yan C, Zhang L, et al. Comparison of ordinary cannulated compression screw and double-head cannulated compression screw fixation in vertical femoral neck fractures[J]. Biomed Res Int, 2020, 2020: 2814548.
[41] Giordano V, Alves DD, Paes RP, et al. The role of the medial plate for Pauwels type Ⅲ femoral neck fracture: a comparative mechanical study using two fixations with cannulated screws[J]. J Exp Orthop, 2019, 6(1): 18.
[42] Zhan S, Jiang D, Xu J, et al. Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis[J]. BMC Musculoskelet Disord, 2020, 21(1): 842.
[43] Zeng W, Liu Y, Hou X. Biomechanical evaluation of internal fixation implants for femoral neck fractures: a comparative finite element analysis[J]. Comput Methods Programs Biomed, 2020, 196: 105714.
[44] 高超界, 刘丹平, 李成, 等. 两种方法治疗垂直不稳定型股骨颈骨折的近期疗效对比[J]. 广东医学, 2020, 41(22):2303-2306.
[45] Su Z, Liang L, Hao Y. Medial femoral plate with cannulated screw for Pauwels type Ⅲ femoral neck fracture: a meta-analysis[J]. J Back Musculoskelet Rehabil, 2021, 34(2): 169-177.
[46] Kuan FC, Yeh ML, Hong CK, et al. Augmentation by cerclage wire improves fixation of vertical shear femoral neck fractures: a biomechanical analysis[J]. Injury, 2016, 47(10): 2081-2086.

备注/Memo

备注/Memo:
通信作者: 张伟 E-mail: orthozhang_wei@163.com