索引超出了数组界限。 文章摘要
|本期目录/Table of Contents|

[1]姜华锋,周新社.全髋关节置换术中重建股骨偏心距研究进展[J].国际骨科学杂志,2018,01:21-23,32.
点击复制

全髋关节置换术中重建股骨偏心距研究进展(PDF)

《国际骨科学杂志》[ISSN:1673-7083/CN:31-1952/R]

期数:
2018年01期
页码:
21-23,32
栏目:
综述
出版日期:
2018-01-30

文章信息/Info

Title:
-
作者:
姜华锋周新社
233004, 蚌埠医学院第一附属医院
Author(s):
-
关键词:
全髋关节置换 股骨 偏心距
Keywords:
-
分类号:
-
DOI:
10.3969/j.issn.1673-7083.2018.01.006
文献标识码:
A
摘要:
重建股骨偏心距(FO)对全髋关节置换术(THA)后髋关节生物力学恢复起着至关重要的作用。大量文献报道,THA后患髋功能、假体寿命及术后并发症与FO是否重建密切相关,重建FO方法包括增加股骨假体颈长度和保留股骨矩、减小颈干角、股骨转子间截骨、高偏心距假体、髋臼组件侧方内移及组合式假体。此外,术前X线片和CT影像、术中测量及术中髋关节周围软组织张力试验结合运用可在THA中实现FO个体化重建。该文就FO对髋关节生物力学重建、THA后常见并发症及重建策略研究进展作一综述。
Abstract:
-

参考文献/References

[1] Mahmood SS, Al-Amiry B, Mukka SS, et al. Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty[J]. Skeletal Radiol, 2015, 44(3): 345-351.
[2] Arnould A, Boureau F, Benad K, et al. Computed tomography evaluation of hip geometry restoration after total hip resurfacing[J]. Orthop Traumatol Surg Res, 2015, 101(5): 571-575.
[3] Clement ND, Patrick-Patel R, MacDonald D, et al. Total hip replacement: increasing femoral offset improves functional outcome[J]. Arch Orthop Trauma Surg, 2016, 136(9): 1317-1323.
[4] Sariali E, Klouche S, Mouttet A, et al. The effect of femoral offset modification on gait after total hip arthroplasty[J]. Acta Orthop, 2014, 85(2): 123-127.
[5] Toepfer CN, West TG, Ferenczi MA.Revisiting frank-starling: regulatory light chain phosphorylation alters the rate of force redevelopment(ktr)in a length-dependent fashion[J]. J Physiol, 2016, 594(18): 5237-5254.
[6] Geijer M, Rundgren G, Weber L, et al. Effective dose in low-dose CT compared with radiography for templating of total hip arthroplasty[J]. Acta Radiol, 2017, 58(10): 1276-1282.
[7] Weber M, Woerner M, Springorum R, et al. Fluoroscopy and imageless navigation enable an equivalent reconstruction of leg length and global and femoral offset in THA[J]. Clin Orthop Relat Res, 2014, 472(10): 3150-3158.
[8] Liebs TR, Nasser L, Herzberg W, et al. The influence of femoral offset on health-related quality of Life after total hip replacement[J]. Bone Joint J, 2014, 96B(1): 36-42.
[9] Falez F, Papalia M, Favetti F, et al. Total hip arthroplasty instability in Italy[J]. Int Orthop, 2017, 41(3): 635-644.
[10] Vicenti G, Solarino G, Spinarelli A, et al. Restoring the femoral offset prevent early migration of the stem in total hip arthroplasty: an EBRA-FCA study[J]. J Biol Regul Homeost Agents, 2016, 30(4 Suppl 1): 207-212.
[11] Jinno T, Koga D, Asou Y, et al. Intraoperative evaluation of the effects of femoral component offset and head size on joint stability in total hip arthroplasty[J]. J Orthop Surg(Hong Kong), 2017, 25(1): 2309499016684298.
[12] Kochbati R, Rbai H, Jlailia M, et al. Predictive factors of aseptic loosening of cemented total hip prostheses[J]. Pan Afr Med J, 2016, 24: 260.
[13] Charles MN, Bourne RB, Davey JR, et al. Soft-tissue balancing of the hip: the role of femoral offset restoration[J]. Instr Course Lect, 2005, 54(5): 131-141.
[14] Lan T, Xiao J, Shi Z. Correlations between polyethylene wear direction and other influencing factors in total hip arthroplasty[J]. Zhonghua Yi Xue Za Zhi, 2014, 94(43): 3416-3420.
[15] De Fine M, Romagnoli M, Toscano A, et al. Is there a role for femoral offset restoration during total hip arthroplasty? A systematic review[J]. Orthop Traumatol Surg Res, 2017, 103(3): 349-355.
[16] Dastane M, Dorr LD, Tarwala R, et al. Hip offset in total hip arthroplasty: quantitative measurement with navigation[J]. Clin Orthop Relat Res, 2011, 469(2): 429-436.
[17] Renkawitz T, Weber T, Dullien S, et al. Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics[J]. Gait Posture, 2016, 49: 196-201.
[18] Wedemeyer C, Quitmann H, Xu J, et al. Digital templating in total hip arthroplasty with the Mayo stem[J]. Arch Orthop Trauma Surg, 2008, 128(10): 1023-1029.
[19] Hayashi S, Nishiyama T, Fujishiro T, et al. Excessive femoral offset does not affect the range of motion after total hip arthroplasty[J]. Int Orthop, 2013, 37(7): 1233-1237.
[20] Zhang G, Yang C, Yang G, et al. Comparison of prosthesis with different neck-shaft angles for reconstruction of femoral proximal anatomy after total hip arthroplasty[J]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi, 2016, 30(1): 30-34.
[21] Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA[J]. Clin Orthop Relat Res, 2004, 429: 73-79.
[22] 汤宇, 孙天胜. 股骨偏心距与全髋关节置换术后假体功能及相关生物力学的变化[J]. 中国临床康复, 2006, 10(33): 133-135.
[23] Terrier A, Levrero Florencio F, Rüdiger HA. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy[J]. Clin Orthop Relat Res, 2014, 472(10): 3159-3165.
[24] Flecher X, Ollivier M, Argenson JN. Lower limb length and offset in total hip arthroplasty[J]. Orthop Traumatol Surg Res, 2016, 102(1 Suppl): S9-S20.
[25] Traina F, De Fine M, Tassinari E, et al. Modular neck prostheses in DDH patients: 11-year results[J]. J Orthop Sci, 2011, 16(1): 14-20.
[26] Mencière ML, Amouyel T, Taviaux J, et al. Fracture of the cobalt-chromium modular femoral neck component in total hip arthroplasty[J]. Orthop Traumatol Surg Res, 2014, 100(5): 565-568.
[27] De Martino I, Assini JB, Elpers ME, et al. Corrosion and fretting of a modular hip system: a retrieval analysis of 60 rejuvenate stems[J]. J Arthroplasty, 2015, 30(8): 1470-1475.
[28] Martin JR, Camp CL, Wyles CC, et al. Increased femoral head offset is associated with elevated metal Ions in asymptomatic patients with metal-on-polyethylene total hip arthroplasty[J]. J Arthroplasty, 2016, 31(12): 2814-2818.
[29] Duwelius PJ, Burkhart B, Carnahan C, et al. Modular versus nonmodular neck femoral implants in primary total hip arthroplasty: which is better?[J]. Clin Orthop Relat Res, 2014, 472(4): 1240-1245.

备注/Memo

备注/Memo:
通信作者: 周新社 E-mail: zhouxs1967@126.com
更新日期/Last Update: 2018-01-30